Electrical characteristics (test at room temperature)
Rated input voltage: 100-240 VAc
Input voltage range: 90-264 VAc
Maximum input current: less than or equal to 0.2A
Input inrush current: Less than or equal to 10A
The maximum input voltage: less than or equal to 270 VAc
Enter slow start: less than or equal to 50 MS
Low efficiency of input voltage: Vin=110VAc, the output load is greater than or equal to 69%
High voltage input efficiency: Vin=220VAc, the output load is greater than or equal to 70%
Long term reliability: MTBF is more than or equal to 100000H
No-load rated output voltage: +5 + 0.1 VDc
Full rated output voltage: +5 + 0.2 VDc
Short time maximum output current:More than 1000MA
Long time maximum output current: More than 600MA
The voltage regulation rate:+ 0.2 %
Load regulation: + 0.5%
The output ripple and noise(mVp-p): less than or equal to 50
Rated input voltage, output load. With 20MHz bandwidth oscilloscope,
The load capacitance test and 10uF and 0.1uF.
Switch machine overshoot: (the rated input voltage, output load is less than or equal to 5 and 10%) %VO
Output over-current protection: The maximum load of 150-200%A
Output short circuit protection: The normal output short-circuit, short circuit is removed automatically resume normal work
Environmental conditions
Working temperature: -20 - +60 degree
Storage temperature: -40 - +80 degree
Relative humidity: 5 - 95%
Cooling mode: Natural cooling
Atmospheric pressure: 80 - 106 Kpa
Altitude: less than or equal to 2000M
Vibration: Vibration coefficient of 10~500Hz, 2G10min./1cycle, 60min.each along X, Y, Z axes
Safety and electromagnetic compatibility
Input design uses UL authentication 0.5A insurance;
PCB plate with double-sided copper-clad plate making, material fire protection class is 94-V0
Safety standards in line with UL1012, EN60950, UL60950
Insulation voltage I/P-O/P:2500VAC
Insulation resistance I/P-O/P>100M Ohms/500VDC 25 C 70% RH
Conduction and radiation in accordance with EN55011, EN55022 (CISPR22)
Electrostatic discharge IEC/EN 61000-4-2 level 4 8kV/15kV
RF immunity IEC/EN 61000-4-3
Temperature Shengan gage design
At room temperature, surface temperature of the power capacitor, converter or maximum of not more than 90 degree